International Harvester

886

Make: International Harvester

Model: 886

Hydraulic System: Open Center System

Maximum Pressure: 2250 PSI

Maximum Flow: 13 GPM

In the 86 Series trac­tors with open cen­ter sys­tems, the hydraulic sys­tem was not designed for con­tin­u­ous hydraulic demand at the remote valves. These trac­tors will require the Ace Pump IHK-86 kit for sprayer pump oper­a­tion. Refer to Ace form 4013‑A for com­plete instal­la­tion instruc­tions. Ref­er­ence the Inter­na­tion­al Har­vester Ser­vice Bul­letin S‑3436 dat­ed March 311977

Select mod­el FMC-HYD-210 when pump­ing pres­sures between 60 and 100 PSI are required. 

Pump Model: FMC-HYD-210

FMC-HYD-210

Port Sizes: 1-1/4" X 1"

Max Flow: 100 GPM

Maximum Shutoff Pressure: 100 PSI

Pump Model: FMC-150-HYD-206

FMC-150-HYD-206

Port Sizes: 1-1/2" X 1-1/4"

Max Flow: 120 GPM

Maximum Shutoff Pressure: 120 PSI

Pump Model: FMC-200-HYD-210/304

FMC-200-HYD-210/304

Port Sizes: 2" X 1-1/2"

Max Flow: 200 GPM

Maximum Shutoff Pressure: 80 (210) / 120 (304) PSI

Installation Instructions for Open Center System

Installation Instructions for Open Center System

1. Shut off all flow from ACE pump.
2. Install pressure gauge between pump and shut off valve.
3. Open Bypass Adjusting Screw 3 or 4 turns.
4. Set tractor throttle to speed at which you will be spraying.
5. Move hydraulic lever to "Lower/Retract" to start pump.
6. Turn Bypass Adjusting Screw clockwise until pressure gauge on sprayer reads between 60 and 100psi. Tighten jam nut.
7. Open sprayer agitation valve to get desired spraying pressure.