TS125A
Make: New Holland
Model: TS125A
Hydraulic System: Open Center System
Maximum Pressure: 2970 PSI
Maximum Flow: 19.8 GPM
On certain Case and New Holland tractors a 710362010 MANUAL DENTENT KIT must be obtained from your Case/New Holland dealer to operate a hydraulic driven pump. This kit converts from a 4 position detent kick-out to a 4 position with detents in all positions. This valve will not return to neutral under pressure over 2000 psi (137.9 bar).
This model has multiple hydraulic systems available. Verify system type for proper pump selection and setup.
Pump Model: FMC-HYD-310

Pump Model: FMC-200-HYD-310

Installation Instructions for Open Center System

1. Shut off all flow from ACE pump.
2. Install pressure gauge between pump and shut off valve.
3. Open Bypass Adjusting Screw 3 or 4 turns.
4. Set tractor throttle to speed at which you will be spraying.
5. Move hydraulic lever to "Lower/Retract" to start pump.
6. Turn Bypass Adjusting Screw clockwise until pressure gauge on sprayer reads between 60 and 100psi. Tighten jam nut.
7. Open sprayer agitation valve to get desired spraying pressure.