White

80

Make: White

Model: 80

Hydraulic System: Open Center System

Maximum Pressure: 2200 PSI

Maximum Flow: 20 GPM

Con­nect the hydraulic hoses from the Ace sprayer pump to the Pow­er Beyond Cir­cuit rather than using the remote hydraulic ports. 

Pump Model: FMC-HYD-310

FMC-HYD-310

Port Sizes: 1-1/4" X 1"

Max Flow: 90 GPM

Maximum Shutoff Pressure: 100 PSI

Pump Model: FMC-200-HYD-310

FMC-200-HYD-310

Port Sizes: 2" X 1-1/2"

Max Flow: 200 GPM

Maximum Shutoff Pressure: 120 PSI

Installation Instructions for Open Center System

Installation Instructions for Open Center System

1. Shut off all flow from ACE pump.
2. Install pressure gauge between pump and shut off valve.
3. Open Bypass Adjusting Screw 3 or 4 turns.
4. Set tractor throttle to speed at which you will be spraying.
5. Move hydraulic lever to "Lower/Retract" to start pump.
6. Turn Bypass Adjusting Screw clockwise until pressure gauge on sprayer reads between 60 and 100psi. Tighten jam nut.
7. Open sprayer agitation valve to get desired spraying pressure.